Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Year range
1.
RGO (Porto Alegre) ; 68: e20200005, 2020. tab
Article in English | LILACS-Express | LILACS | ID: biblio-1091885

ABSTRACT

ABSTRACT Objective to analyze the surface roughness and color stability of the composite resin after surface treatment with the aluminum oxide discs and subsequent exposure to the Advanced Teeth Whitening Strips. Methods 20 specimens of the Filtek Z350XT restorer (3M®) were prepared and daily subjected to home bleaching for 30 minutes during 14 days. A precision rugosimeter was used in order to verify the roughness by means of 3 random readings in the same direction in each sample. For color stability the CIELAB system (L*, a*, b* values) was used through the spectrophotometer (MINOLTA CR -321, Japan). The means of the test specimens as well as the mean of each group were calculated using the random readings. Data statistical analysis were performed by ANOVA- analysis of variance. The level of significance was set at 5% (p ≤ 0.05). Results Roughness did not present great numerical variations. No statistically significant difference between the means obtained concerning the surface roughness of the composite resin with p = 0.44 was observed. However, it was found that there was a statistically significant difference between the means obtained in relation to the color stability of the composite resin, p=0. 007. Conclusion It was concluded that pre-contoured strips containing 6% hydrogen peroxide do not have a significant adverse effect on the roughness of Z350XT (3M®) resin. However, it was also concluded that according to the color stability analysis performed, there may be an indication of the restoration replacement after the bleaching treatment, due to their color change.


RESUMO Objetivo Analisar a rugosidade superficial e a estabilidade da cor da resina composta após tratamento de superfície com os discos de óxido de alumínio e posterior exposição à fita clareadora Advanced Teeth Whitening Strips. Métodos Foram confeccionados 20 corpos de prova do restaurador universal Filtek Z350XT (3M®), estes, foram submetidos ao clareamento caseiro por 30 minutos diários durante 14 dias. Utilizou-se um rugosímetro de precisão para verificação da rugosidade através de 3 leituras aleatórias no mesmo sentido em cada amostra, e para estabilidade de cor foi utilizado o sistema CIELAB (valores L*, a*, b*), através do espectofotômetro (MINOLTA CR-321, Japão). As leituras coletadas possibilitaram o cálculo das médias dos corpos de prova e a média de cada grupo. Em seguida, os dados foram submetidos a tratamento estatístico pela análise de variância ANOVA. O nível de significância estabelecido foi de 5% (p≤0,05). Resultados a rugosidade não sofreu grandes variações numéricas e também não houve diferença estatisticamente significantes entre as médias obtidas em relação a rugosidade superficial da resina composta (p=0,44). Contudo, verificou-se que houve diferenças estatisticamente significantes entre as medias obtidas em relação à estabilidade de cor da resina composta, com p= 0,007. Conclusão As fitas pré-contornadas contendo peróxido de hidrogênio a 6% não provocam efeito adverso significantes sobre a rugosidade da resina Z350XT (3M®). Contudo, também concluímos que, de acordo com a análise de estabilidade de cor realizada, poderá haver indicação da substituição das restaurações após o tratamento clareador devido à alteração na coloração das mesmas.

2.
HU rev ; 45(3): 244-253, 2019.
Article in Portuguese | LILACS | ID: biblio-1048967

ABSTRACT

Introdução: Como uma opção de tratamento ao edentulismo mandibular foi desenvolvido o conceito All-on-4®, uma técnica de ancoragem com a instalação de quatro implantes distribuídos na região anterior da mandíbula edêntula para uma reabilitação total implantossuportada. Objetivo: Neste estudo, analisamos pelo método de elementos finitos o comportamento biomecânico dos implantes e tecidos ósseos. Material e métodos: Foram utilizados 3 modelos tridimensionais computadorizados, cada um com 4 implantes hexágono externo 3,75x13mm na região interforames mentuais, os implantes anteriores mantidos na posição axial e a variação ocorreu nos implantes posteriores: grupo 1, implantes posteriores retos; grupo 2, implantes posteriores com inclinação em 17° e grupo 3, com implantes posteriores inclinados em 30°. Uma carga axial de 150N foi aplicada nos molares e de 100N nos pré-molares bilateralmente. Resultados: Após análises evidenciou-se que nos grupos 17° (13,68Mpa, 34,76Mpa e 14,36Mpa para as tensões de tração, compressão e cisalhamento respectivamente) e 30° (14,26Mpa, 23,14Mpa e 10,31Mpa para as tensões de tração, compressão e cisalhamento respectivamente) apresentaram menores picos de tensão no osso. O mesmo padrão de distribuição de tensões foi observado para os implantes, com redução quando inclinamos os implantes distais. Conclusão: Os resultados mostraram que a angulação dos implantes favoreceu a distribuição das tensões no osso e implantes, interferindo positivamente na performance biomecânica das reabilitações totais implantossuportadas em mandíbulas edêntulas, considerando que no grupo dos implantes retos os valores das tensões foram maiores.


Introduction: As a treatment option for mandibular edentulism, the All-on-4® concept was developed, an anchoring technique with the installation of four implants distributed in the anterior region of the edentulous mandible for total implant-supported rehabilitation. Objective: In this study, we analyzed by the finite element method the biomechanical behavior of implants and bone tissues. Material and methods: Three computerized three-dimensional models were used, each with 4 external hexagon 3.75x13mm implants in the mental interforam region, the anterior implants kept in the axial position and the variation occurred in the posterior implants: group 1, straight posterior implants; group 2, posterior implants inclined at 17° and group 3, posterior implants inclined at 30°. An axial load of 150 N was applied to the molars and 100 N to the premolars bilaterally. Results: After analysis, it was found that in the 17° (13.68Mpa, 34.76Mpa and 14.36Mpa groups for tensile, compressive and shear stresses respectively) and 30 ° (14.26Mpa, 23.14Mpa and 10.31Mpa for tensile, compressive and shear stresses respectively) presented lower stress peaks in the bone. The same pattern of stress distribution was observed for the implants, with reduction when the distal implants were tilted. Conclusion: The results showed that the angulation of the implants favored the distribution of stresses in the bone and implants, positively interfering in the biomechanical performance of the total implant-supported rehabilitations in edentulous jaws, considering that in the group of straight implants the stress values were higher.


Subject(s)
Humans , Tissues , Bicuspid , Bone and Bones , Molar , Mouth Rehabilitation , Jaw, Edentulous, Partially , Dental Implantation , Mandible
3.
HU rev ; 44(1): 29-34, 2018.
Article in Portuguese | LILACS | ID: biblio-981864

ABSTRACT

O avanço tecnológico tem se mostrado um grande aliado em diversas áreas, assim como na odontologia. O surgimento da tecnológica CAD/CAM (Computer Aided Design/Computer Aided Manufacturing) na década de 1950 trouxe outra realidade para a prática clínica diária. Previamente todo o processo laboratorial de trabalhos protéticos era demorado e puramente físico, atualmente a fabricação das peças protéticas demanda um menor tempo devido a utilização do meio digital, o que consequentemente diminui as consultas aos Cirurgiões-Dentistas. A adição de ferramentas digitais no planejamento e na execução dos tratamentos odontológicos alterou completamente o workflow, fazendo com que a busca para um aperfeiçoamento seja constante visando sempre o melhor atendimento e qualidade dos tratamentos realizados. Dessa forma este trabalho tem o objetivo de realizar uma revisão crítica da literatura sobre a aplicabilidade clínica da tecnologia CAD-CAM em Odontologia.


The technological advance has been shown to be a greatly in several areas, as well as in dentistry. The emergence of the technological CAD / CAM (Computer Aided Design / Computer Aided Manufacturing) in the 1950s brought another reality to daily clinical practice. Previously, the entire laboratory process of prosthetic work was time consuming and purely physical, currently the manufacture of prosthetic work requires less time due to the use of the digital medium, which consequently decreases the dentist appointments. The addition of digital tools in the planning and execution of dental treatments has completely altered the workflow, making the search for a constant improvement, always aiming at the best care and quality of treatment performed. Thus, this paper has the objective of performing a critical review of the literature on the clinical applicability of CAD / CAM technology in dentistry.


Subject(s)
Technology, Dental , Dentistry , Computers , Technological Development , Computer-Aided Design , Printing, Three-Dimensional
SELECTION OF CITATIONS
SEARCH DETAIL